Search results for "Food irradiation"
showing 10 items of 20 documents
Detection of Irradiated Food and Evaluation of the Given Dose by Electron Spin Resonance, Thermoluminescence, and Gas Chromatographic/Mass Spectromet…
2018
Abstract The treatment of food with ionizing radiation, at doses lower than 10 kGy, is a preservation technology, which can be used to reduce food spoilage due to microorganisms and to decrease insect infestation, enhancing, in the same time, the hygienic quality, extending the shelf life of food itself. In order to increase the general consumer acceptance and accordingly to facilitate the commercialization and trade of irradiated food, the European Committee for Standardization (CEN) validated reliable analytical techniques to identify irradiated foodstuffs for legal control purposes, distinguished in Chemical, Physical, and Microbiological ones, depending on the characteristics of marker …
A practical and transferable methodology for dose estimation in irradiated spices, based on thermoluminescence dosimetry
2008
Abstract The thermoluminescence technique is recommended by the European Committee for Standardization for the detection of irradiated food containing silicates as contaminants. In this work, the applicability of the thermoluminescence technique as a quantitative method to assess the original dose in irradiated oregano was studied; the additive-dose method was used, with reirradiation doses up to 600 Gy. The proposed new procedure allows to clearly discriminate irradiated from unirradiated samples, even after one year storage, and it gives an acceptable estimation of the original dose; the overall modified procedure requires only one day to be completed.
The additive dose method for dose estimation in irradiated oregano by thermoluminescence technique
2009
The ionizing radiation treatment of food is nowadays a worldwide recognized tool for food preservation, provided that proper and validated identification methods are available and used. The thermoluminescence (TL) technique is one of the physical methods recommended by the European Committee for Standardization to distinguish irradiated from not irradiated samples, for food containing silicate minerals as contaminants, such as spices and aromatic herbs, which are among the most frequently irradiated foods. The experimental results presented in this work show that, at least up to the highest tested doses (2 kGy), it is possible to set up a procedure to estimate the actual dose in the irradia…
Assessment of contamination of <em>Salmonella</em> spp. in imported black pepper and sesame seed and salmonella inactivation by gamma irr…
2021
This study shows the frequency of seeds samples contaminated by Salmonella spp. collected randomly from local markets; on 30 black pepper sample no contaminated sample was found while Salmonella spp. was detected in 3 of 36 (8.3%) analyzed sesame samples; three different serotypes were identified: S. Montevideo, S. Stanleyville e S. Tilene. The efficacy of gamma irradiation to inactivate Salmonella Montevideo in black pepper and sesame irradiated between 1 and 5 kGy was evaluated. 3 kGy is sufficient to reduce of 3-4 log CFU/g; whereas 5 kGy have been need to reduce 5.5-6 log CFU/g for samples of black pepper and sesame. No statistically significant differences were found between black pepp…
Irradiated foods between concern and acceptance in the Italian market
2018
Consumers have always shown a marked concern for the novel technologies. The treatment of foods with ionizing radiation, not entirely new, has always been a major concern among consumers for the impact that the consumption of treated food could have on health. The aim of this paper is to investigate Italian consumer attitudes towards the irradiated food and in particular the perceived risk and the acceptability of these technology. A survey was carried out in Italy by administering an on-line questionnaire to a sample of 392 consumers. The results of the study highlight a low level of knowledge of food irradiation, often associated with nuclear radiation and doubts about the effect that the…
The gas chromatography/mass spectrometry can be used for dose estimation in irradiated pork
2009
Abstract Food safety can be improved using ionizing radiation to reduce food spoilage and to extend its shelf life. The gas chromatography/mass spectrometry (GC/MS) has been validated by the European Community as a powerful method to identify irradiated food containing fat. The preliminary goals of our research were: (i) to set up this method, based on the detection of radiation induced 2-dodecylcyclobutanones (2-DCB) in pork muscle samples and (ii) to check the microbiological efficacy of the treatment. The main objective was to render the GC/MS a quantitative technique for dose estimation, through the measurement of the 2-DCB concentration in the irradiated sample. Our results show that t…
An inter-laboratory comparison to evaluate the suitability of EN 1787 standard to detect irradiation in plant-origin foods with health benefits
2020
Abstract This paper reports the results of a study carried out to verify the applicability of the EN 1787 method, which uses the Electron Spin Resonance (ESR) technique for the identification of irradiated plant-origin foods with health benefits. The method was tested on samples of herbal ingredients of Plant Food Supplements (PFSs), nuts and fresh blueberries. Untreated and irradiated samples of Camellia sinensis (leaves) Ginkgo biloba (leaves), Glycine max (seeds), Silybum marianum (fruits), Vaccinium myrtillus (fruits), almonds, hazelnuts, peanuts, pistachios, walnuts and fresh blueberries were analysed. The work includes an inter-laboratory blind test involving five Italian laboratories…
Assessment of contamination of Salmonella spp. in imported black pepper and sesame seed and salmonella inactivation by gamma irradiation
2021
This study shows the frequency of seeds samples contaminated by Salmonella spp. collected randomly from local markets; on 30 black pepper sample no contaminated sample was found while Salmonella spp. was detected in 3 of 36 (8.3%) analyzed sesame samples; three different serotypes were identified: S. Montevideo, S. Stanleyville e S. Tilene. The efficacy of gamma irradiation to inactivate Salmonella Montevideo in black pepper and sesame irradiated between 1 and 5 kGy was evaluated. 3 kGy is sufficient to reduce of 3-4 log CFU/g; whereas 5 kGy have been need to reduce 5.5-6 log CFU/g for samples of black pepper and sesame. No statistically significant differences were found between black pepp…
Mycotoxin contamination of animal feedingstuff: detoxification by gamma irradiation and reduction of aflatoxins and ochratoxin A concentrations
2014
Mycotoxins are fungal secondary metabolites identified in many agricultural products screened for toxigenic moulds. They have been reported to be carcinogenic, teratogenic, tremorogenic, haemorrhagic and dermatitic to a wide range of organisms. With the increasing stringent regulations for mycotoxins imposed by importing countries such as those of the European Union, many cereals that are not safe for human consumption are used in formulations intended for animal feed. Gamma-rays are reported in the scientific literature to destroy ochratoxin A and aflatoxin in food crops and feed. The present study provides preliminary data for establishing the effect of dose of gamma-irradiation, ranging …
Qualitative and quantitative thermoluminescence analysis on irradiated oregano
2007
Abstract Thermoluminescence (TL) dosimetry is one of the physical methods used for the identification of irradiated food, suitable for foods from which silicate minerals can be extracted. The aims of the present work were to apply the TL analysis for a qualitative identification of irradiated oregano, and to set up a quantitative procedure to estimate the original treatment dose on the sample. The experimental results show that the TL analysis allows to distinguish irradiated oregano even seven months after the treatment. The additive dose procedure gives a rough estimation of the treatment dose, but can be helpful when the TL ratio method is unsatisfactory.